Correlation between sweat and blood biomarkers for physiological monitoring in humans: a scoping review

Autores

  • Rebeca Trigueiro Maximo Universidade Federal de Pernambuco
  • Marilú Gomes Netto Monte da Silva Universidade Federal de Pernambuco
  • Danyelly Bruneska Gondim Martins Universidade Federal de Pernambuco
  • Patricia Smith Cavalcante Universidade Federal de Pernambuco
  • Patricia Tedesco Universidade Federal de Pernambuco
  • Rosalie Barreto Belian Universidade Federal de Pernambuco
  • Ricardo Yara Universidade Federal de Pernambuco

DOI:

https://doi.org/10.36560/19520262251

Palavras-chave:

Health monitoring; Non-invasive monitoring; Physiological biomarkers; Sweat analysis; Sweat–blood correlation

Resumo

Continuous, real-time health monitoring has driven growing interest in non-invasive biochemical strategies, highlighting human sweat as a promising biofluid due to its rich biomarker composition. Despite advances in the development of sweat-based wearable sensors, the lack of clinically validated standards and inconsistencies in the correlations between sweat and blood analytes—considered the gold standard in clinical practice—still limit their widespread application. These discrepancies arise from physiological and methodological factors, including secretion mechanisms, sweat rates, induction and collection methods, and skin contamination. This review critically compiles and analyzes the available evidence on the relationship between sweat and blood biomarkers, identifying existing gaps, methodological limitations, and future perspectives, and emphasizing the need for approaches grounded in the physiology of sweat glands to advance non-invasive physiological monitoring.

Referências

ADELAARS, S. et al. The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study. Clinical Chemistry and Laboratory Medicine, v. 62, n. 6, p. 1118–1125, 2024.

ARKSEY, H.; O'MALLEY, L. Scoping studies: towards a methodological framework. International Journal of Social Research Methodology, v. 8, n. 1, p. 19–32, 2005.

BAKER, L. B.; WOLFE, A. S. Physiological mechanisms determining eccrine sweat composition. European Journal of Applied Physiology, v. 120, n. 4, p. 719–752, 2020.

BANDODKAR, A. J.; GHAFFARI, R.; ROGERS, J. A. Don't sweat it: The quest for wearable stress sensors. Matter, v. 2, n. 4, p. 795–797, 2020.

BERNARDO, V. R. et al. Comparative analysis among blood pressure devices, from different brands, used in the pharmaceutical clinic service in a public pharmacy, Sinop-MT. Scientific Electronic Archives, v. 13, n. 11, p. 82-88, 2020.

CAMPOS, N. L. R. de et al. Percalços na detecção precoce da pré-eclâmpsia durante pré-natal na Atenção Primária à Saúde. Scientific Electronic Archives, v. 16, n. 12, 2023. DOI: https://doi.org/10.36560/161220231812.

CHILDS, A. et al. Diving into sweat: Advances, challenges, and future directions in wearable sweat sensing. ACS Nano, v. 18, n. 36, p. 24605–24616, 2024.

CINCA-MORROS, S. et al. A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: A review. Analytica Chimica Acta, v. 1327, n. 342988, p. 342988, 2024.

CUNHA, A. N.; MASOCHINI, R. G.; JEZUS, S. V. Hypertension in the elderly: an approach to medication adherence. Scientific Electronic Archives, v. 11, n. 2, p. 138–142, 2018. DOI: https://doi.org/10.36560/1122018593.

DAI, J.; LU, J.; ZHOU, D. Cost-effective and portable electrochemical sensing of sweat constituents via printed electrodes. International Journal of Electrochemical Science, v. 20, n. 11, p. 101164, 2025.

DAVIS, B. C. et al. A novel sweat sensor detects inflammatory differential rhythmicity patterns in inpatients and outpatients with cirrhosis. npj Digital Medicine, v. 7, n. 1, p. 382, 2024.

DENG, W.; BAI, J.; ZHOU, M. Skin-interfaced entirely self-contained wearable biosensor for the noninvasive and dynamic monitoring of sweat myo-inositol. ACS Sensors, v. 10, n. 7, p. 5166–5175, 2025.

GIMENEZ, D. M. J.; JESUS, M. C. M. de; CARMINATI, T. D. S. M. Liderança - Desafios e atributos do profissional enfermeiro na prática como gestor. Scientific Electronic Archives, v. 19, n. 2, 2026. DOI: https://doi.org/10.36560/19220262043.

HATTORI, M.; YASHIRO, K. Short report: Estimating blood lactate dynamics from sweat lactate and sweat rate after high-intensity exercise - A pilot regression-based study. Open Access Journal of Sports Medicine, v. 16, p. 99–105, 2025.

JAJACK, A. et al. Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland. PLoS One, v. 13, n. 7, p. e0200009, 2018.

JIN, Y. et al. A dried sweat spot paper (DSSP) method based on novel mass spectrometry probe labeling for detection and resolution of DL-lactate enantiomers as potential biomarkers for diabetes mellitus. Analytica Chimica Acta, v. 1317, n. 342914, p. 342914, 2024.

KLOUS, L. et al. The (in)dependency of blood and sweat sodium, chloride, potassium, ammonia, lactate and glucose concentrations during submaximal exercise. European Journal of Applied Physiology, v. 121, n. 3, p. 803–816, 2021.

KRAEMER, W. J. et al. Cortitrol supplementation reduces serum cortisol responses to physical stress. Metabolism: Clinical and Experimental, v. 54, n. 5, p. 657–668, 2005.

LAOCHAI, T. et al. Touch–based potentiometric sensors for simultaneous detection of urea and ammonium from fingertip sweat. Sensors and Actuators. B, Chemical, v. 413, n. 135898, p. 135898, 2024.

LEVAC, D.; COLQUHOUN, H.; O'BRIEN, K. K. Scoping studies: advancing the methodology. Implementation Science, v. 5, n. 1, p. 69, 2010.

LI, G. et al. Wearable hydrogel SERS chip utilizing plasmonic trimers for uric acid analysis in sweat. Nano Letters, v. 24, n. 42, p. 13447–13454, 2024.

LU, F.; YANG, J. H.; KOH, A. Hydrophilic skin-interfaced microfluidic devices for comprehensive sweat collection and analysis. Lab on a Chip, v. 25, n. 24, p. 6550–6570, 2025.

MELGAREJO, A. P.; ZAMPIERON, R. G.; SHENG, L. Y. Cuidado farmacêutico: atuação e contribuição do farmacêutico no SUS, Sinop - MT. Scientific Electronic Archives, v. 14, n. 6, 2020. DOI: https://doi.org/10.36560/14620211298.

MENDES, S. C. et al. Diabetics: Epidemiological profile and knowledge about the complications of diabetes mellitus. Scientific Electronic Archives, v. 12, n. 5, p. 111-120, 2019.

MENG, K. et al. Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions. Biosensors & Bioelectronics, v. 287, n. 117677, p. 117677, 2025.

MESSINA, L.; AMADORO, P.; GIARDI, M. T. Advances in electrochemical nanobiosensors for noninvasive stress biomarker detection. Sensors, v. 25, n. 23, p. 7255, 2025.

PERINGETH, K. et al. Self-powered microfluidic-based sensor for noninvasive sweat analysis. Sensors and Actuators. B, Chemical, v. 423, n. 136859, p. 136859, 2025.

PETERS, M. D. J. et al. Guidance for conducting systematic scoping reviews. International Journal of Evidence-Based Healthcare, v. 13, n. 3, p. 141–146, 2015.

PROMPHET, N. et al. Non-invasive fingertip sweat biosensor for early kidney disease biomarker screening. Sensors and Actuators. B, Chemical, v. 441, n. 137967, p. 137967, 2025.

RAYYAN. Rayyan: AI-powered systematic review management platform. Disponível em: https://www.rayyan.ai/. Acesso em: 20 jul. 2026.

RODRIGUES, L. L.; SANTOS, R. M. Vegetarian diet and the relationship with sport. Scientific Electronic Archives, v. 14, n. 7, p. 96–101, 2021. DOI: https://doi.org/10.36560/14720211373.

SAHA, T. et al. Osmotically enabled wearable patch for sweat harvesting and lactate quantification. Micromachines, v. 12, n. 12, p. 1513, 2021.

SAHA, T. et al. A passive perspiration inspired wearable platform for continuous glucose monitoring. Advanced Science, v. 11, n. 41, p. e2405518, 2024.

SONNER, Z. et al. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications. Biomicrofluidics, v. 9, n. 3, p. 031301, 2015.

SPANO, J. et al. Investigation of effects of collection conditions on amino acid concentrations in sweat and correlations with their Circulating levels in plasma. Scientific Reports, v. 15, n. 1, p. 23198, 2025.

XUAN, X. et al. Fully integrated wearable device for continuous sweat lactate monitoring in sports. ACS Sensors, v. 8, n. 6, p. 2401–2409, 2023.

YANG, H.; YAN, S. A comprehensive review of electrochemical lactate biosensors: Principles, innovations, and future perspectives. International Journal of Electrochemical Science, v. 20, n. 10, p. 101132, 2025.

YANG, Y. et al. A miniaturized battery-free wireless epidermal platform for multiplexed sweat biomarker monitoring. Chemical Engineering Journal, v. 522, n. 167787, p. 167787, 2025.

ZHENG, L. et al. A skin-interfaced sensor for noninvasive monitoring of pharmacokinetic and pharmacodynamic responses. Biosensors & Bioelectronics, v. 295, n. 118301, p. 118301, 2026.

ZHENG, Y. A review of wearable sweat monitoring platforms: From biomarker detection to signal processing systems. 2025. Disponível em: http://dx.doi.org/10.1149/osf.io/musp9_v1. Acesso em: 20 jul. 2026.

Publicado

2026-08-17

Como Citar

Maximo, R. T., Silva, M. G. N. M. da, Martins, D. B. G., Cavalcante, P. S., Tedesco, P., Belian, R. B., & Yara, R. (2026). Correlation between sweat and blood biomarkers for physiological monitoring in humans: a scoping review. Scientific Electronic Archives, 19(5), 1–8. https://doi.org/10.36560/19520262251

Edição

Seção

Ciências da Saúde

Artigos Semelhantes

<< < 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 > >> 

Você também pode iniciar uma pesquisa avançada por similaridade para este artigo.