Correlation between sweat and blood biomarkers for physiological monitoring in humans: a scoping review
DOI:
https://doi.org/10.36560/19520262251Keywords:
Health monitoring, Non-invasive monitoring, Physiological biomarkers, Sweat analysis, Sweat–blood correlationAbstract
Continuous, real-time health monitoring has driven growing interest in non-invasive biochemical strategies, highlighting human sweat as a promising biofluid due to its rich biomarker composition. Despite advances in the development of sweat-based wearable sensors, the lack of clinically validated standards and inconsistencies in the correlations between sweat and blood analytes—considered the gold standard in clinical practice—still limit their widespread application. These discrepancies arise from physiological and methodological factors, including secretion mechanisms, sweat rates, induction and collection methods, and skin contamination. This review critically compiles and analyzes the available evidence on the relationship between sweat and blood biomarkers, identifying existing gaps, methodological limitations, and future perspectives, and emphasizing the need for approaches grounded in the physiology of sweat glands to advance non-invasive physiological monitoring.
References
ADELAARS, S. et al. The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study. Clinical Chemistry and Laboratory Medicine, v. 62, n. 6, p. 1118–1125, 2024. DOI: https://doi.org/10.1515/cclm-2023-1285
ARKSEY, H.; O'MALLEY, L. Scoping studies: towards a methodological framework. International Journal of Social Research Methodology, v. 8, n. 1, p. 19–32, 2005. DOI: https://doi.org/10.1080/1364557032000119616
BAKER, L. B.; WOLFE, A. S. Physiological mechanisms determining eccrine sweat composition. European Journal of Applied Physiology, v. 120, n. 4, p. 719–752, 2020. DOI: https://doi.org/10.1007/s00421-020-04323-7
BANDODKAR, A. J.; GHAFFARI, R.; ROGERS, J. A. Don't sweat it: The quest for wearable stress sensors. Matter, v. 2, n. 4, p. 795–797, 2020. DOI: https://doi.org/10.1016/j.matt.2020.03.004
BERNARDO, V. R. et al. Comparative analysis among blood pressure devices, from different brands, used in the pharmaceutical clinic service in a public pharmacy, Sinop-MT. Scientific Electronic Archives, v. 13, n. 11, p. 82-88, 2020. DOI: https://doi.org/10.36560/131120201147
CAMPOS, N. L. R. de et al. Percalços na detecção precoce da pré-eclâmpsia durante pré-natal na Atenção Primária à Saúde. Scientific Electronic Archives, v. 16, n. 12, 2023. DOI: https://doi.org/10.36560/161220231812. DOI: https://doi.org/10.36560/161220231812
CHILDS, A. et al. Diving into sweat: Advances, challenges, and future directions in wearable sweat sensing. ACS Nano, v. 18, n. 36, p. 24605–24616, 2024. DOI: https://doi.org/10.1021/acsnano.4c10344
CINCA-MORROS, S. et al. A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: A review. Analytica Chimica Acta, v. 1327, n. 342988, p. 342988, 2024. DOI: https://doi.org/10.1016/j.aca.2024.342988
CUNHA, A. N.; MASOCHINI, R. G.; JEZUS, S. V. Hypertension in the elderly: an approach to medication adherence. Scientific Electronic Archives, v. 11, n. 2, p. 138–142, 2018. DOI: https://doi.org/10.36560/1122018593.
DAI, J.; LU, J.; ZHOU, D. Cost-effective and portable electrochemical sensing of sweat constituents via printed electrodes. International Journal of Electrochemical Science, v. 20, n. 11, p. 101164, 2025. DOI: https://doi.org/10.1016/j.ijoes.2025.101164
DAVIS, B. C. et al. A novel sweat sensor detects inflammatory differential rhythmicity patterns in inpatients and outpatients with cirrhosis. npj Digital Medicine, v. 7, n. 1, p. 382, 2024. DOI: https://doi.org/10.1038/s41746-024-01404-1
DENG, W.; BAI, J.; ZHOU, M. Skin-interfaced entirely self-contained wearable biosensor for the noninvasive and dynamic monitoring of sweat myo-inositol. ACS Sensors, v. 10, n. 7, p. 5166–5175, 2025. DOI: https://doi.org/10.1021/acssensors.5c01284
GIMENEZ, D. M. J.; JESUS, M. C. M. de; CARMINATI, T. D. S. M. Liderança - Desafios e atributos do profissional enfermeiro na prática como gestor. Scientific Electronic Archives, v. 19, n. 2, 2026. DOI: https://doi.org/10.36560/19220262043. DOI: https://doi.org/10.36560/19220262043
HATTORI, M.; YASHIRO, K. Short report: Estimating blood lactate dynamics from sweat lactate and sweat rate after high-intensity exercise - A pilot regression-based study. Open Access Journal of Sports Medicine, v. 16, p. 99–105, 2025. DOI: https://doi.org/10.2147/OAJSM.S534243
JAJACK, A. et al. Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland. PLoS One, v. 13, n. 7, p. e0200009, 2018. DOI: https://doi.org/10.1371/journal.pone.0200009
JIN, Y. et al. A dried sweat spot paper (DSSP) method based on novel mass spectrometry probe labeling for detection and resolution of DL-lactate enantiomers as potential biomarkers for diabetes mellitus. Analytica Chimica Acta, v. 1317, n. 342914, p. 342914, 2024. DOI: https://doi.org/10.1016/j.aca.2024.342914
KLOUS, L. et al. The (in)dependency of blood and sweat sodium, chloride, potassium, ammonia, lactate and glucose concentrations during submaximal exercise. European Journal of Applied Physiology, v. 121, n. 3, p. 803–816, 2021. DOI: https://doi.org/10.1007/s00421-020-04562-8
KRAEMER, W. J. et al. Cortitrol supplementation reduces serum cortisol responses to physical stress. Metabolism: Clinical and Experimental, v. 54, n. 5, p. 657–668, 2005. DOI: https://doi.org/10.1016/j.metabol.2004.12.010
LAOCHAI, T. et al. Touch–based potentiometric sensors for simultaneous detection of urea and ammonium from fingertip sweat. Sensors and Actuators. B, Chemical, v. 413, n. 135898, p. 135898, 2024. DOI: https://doi.org/10.1016/j.snb.2024.135898
LEVAC, D.; COLQUHOUN, H.; O'BRIEN, K. K. Scoping studies: advancing the methodology. Implementation Science, v. 5, n. 1, p. 69, 2010. DOI: https://doi.org/10.1186/1748-5908-5-69
LI, G. et al. Wearable hydrogel SERS chip utilizing plasmonic trimers for uric acid analysis in sweat. Nano Letters, v. 24, n. 42, p. 13447–13454, 2024. DOI: https://doi.org/10.1021/acs.nanolett.4c04267
LU, F.; YANG, J. H.; KOH, A. Hydrophilic skin-interfaced microfluidic devices for comprehensive sweat collection and analysis. Lab on a Chip, v. 25, n. 24, p. 6550–6570, 2025. DOI: https://doi.org/10.1039/D5LC00703H
MELGAREJO, A. P.; ZAMPIERON, R. G.; SHENG, L. Y. Cuidado farmacêutico: atuação e contribuição do farmacêutico no SUS, Sinop - MT. Scientific Electronic Archives, v. 14, n. 6, 2020. DOI: https://doi.org/10.36560/14620211298. DOI: https://doi.org/10.36560/14620211298
MENDES, S. C. et al. Diabetics: Epidemiological profile and knowledge about the complications of diabetes mellitus. Scientific Electronic Archives, v. 12, n. 5, p. 111-120, 2019. DOI: https://doi.org/10.36560/1252019889
MENG, K. et al. Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions. Biosensors & Bioelectronics, v. 287, n. 117677, p. 117677, 2025. DOI: https://doi.org/10.1016/j.bios.2025.117677
MESSINA, L.; AMADORO, P.; GIARDI, M. T. Advances in electrochemical nanobiosensors for noninvasive stress biomarker detection. Sensors, v. 25, n. 23, p. 7255, 2025. DOI: https://doi.org/10.3390/s25237255
PERINGETH, K. et al. Self-powered microfluidic-based sensor for noninvasive sweat analysis. Sensors and Actuators. B, Chemical, v. 423, n. 136859, p. 136859, 2025. DOI: https://doi.org/10.1016/j.snb.2024.136859
PETERS, M. D. J. et al. Guidance for conducting systematic scoping reviews. International Journal of Evidence-Based Healthcare, v. 13, n. 3, p. 141–146, 2015. DOI: https://doi.org/10.1097/XEB.0000000000000050
PROMPHET, N. et al. Non-invasive fingertip sweat biosensor for early kidney disease biomarker screening. Sensors and Actuators. B, Chemical, v. 441, n. 137967, p. 137967, 2025. DOI: https://doi.org/10.1016/j.snb.2025.137967
RAYYAN. Rayyan: AI-powered systematic review management platform. Disponível em: https://www.rayyan.ai/. Acesso em: 20 jul. 2026.
RODRIGUES, L. L.; SANTOS, R. M. Vegetarian diet and the relationship with sport. Scientific Electronic Archives, v. 14, n. 7, p. 96–101, 2021. DOI: https://doi.org/10.36560/14720211373. DOI: https://doi.org/10.36560/14720211373
SAHA, T. et al. Osmotically enabled wearable patch for sweat harvesting and lactate quantification. Micromachines, v. 12, n. 12, p. 1513, 2021. DOI: https://doi.org/10.3390/mi12121513
SAHA, T. et al. A passive perspiration inspired wearable platform for continuous glucose monitoring. Advanced Science, v. 11, n. 41, p. e2405518, 2024. DOI: https://doi.org/10.1002/advs.202405518
SONNER, Z. et al. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications. Biomicrofluidics, v. 9, n. 3, p. 031301, 2015. DOI: https://doi.org/10.1063/1.4921039
SPANO, J. et al. Investigation of effects of collection conditions on amino acid concentrations in sweat and correlations with their Circulating levels in plasma. Scientific Reports, v. 15, n. 1, p. 23198, 2025. DOI: https://doi.org/10.1038/s41598-025-05051-8
XUAN, X. et al. Fully integrated wearable device for continuous sweat lactate monitoring in sports. ACS Sensors, v. 8, n. 6, p. 2401–2409, 2023. DOI: https://doi.org/10.1021/acssensors.3c00708
YANG, H.; YAN, S. A comprehensive review of electrochemical lactate biosensors: Principles, innovations, and future perspectives. International Journal of Electrochemical Science, v. 20, n. 10, p. 101132, 2025. DOI: https://doi.org/10.1016/j.ijoes.2025.101132
YANG, Y. et al. A miniaturized battery-free wireless epidermal platform for multiplexed sweat biomarker monitoring. Chemical Engineering Journal, v. 522, n. 167787, p. 167787, 2025. DOI: https://doi.org/10.1016/j.cej.2025.167787
ZHENG, L. et al. A skin-interfaced sensor for noninvasive monitoring of pharmacokinetic and pharmacodynamic responses. Biosensors & Bioelectronics, v. 295, n. 118301, p. 118301, 2026. DOI: https://doi.org/10.1016/j.bios.2025.118301
ZHENG, Y. A review of wearable sweat monitoring platforms: From biomarker detection to signal processing systems. 2025. Disponível em: http://dx.doi.org/10.1149/osf.io/musp9_v1. Acesso em: 20 jul. 2026. DOI: https://doi.org/10.1149/osf.io/musp9_v1
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Scientific Electronic Archives

This work is licensed under a Creative Commons Attribution 4.0 International License.
The journal reserves the right to make changes to the original rules, spelling and grammatical order, in order to keep the language of worship default, respecting, however, the style of the authors. The finals will be sent to authors. Articles published are the property of Scientific Electronic Archives magazine, becoming its total or partial reprint, subject to the express authorization of the direction of the journal. The original source of publication should be retained. The originals will not be returned to the authors. Opinions expressed by authors of articles are solely your responsibility.

This journal uses the License Creative Commons Atribui

